Machines
Read the machines you already have
If it speaks Modbus, we can read it: bearing temperatures, motor current, pressures, run status and fault codes from your PLCs, meters and controllers. On screen, with alarms and work orders, next to everything else you run.
What you can watch
Values your machines already measure, read from their controllers.
Bearing temperature
Read from the machine's PLC over Modbus. Too hot, and the alarm raises; from the alarm, the inspection becomes a work order.
Motor current
A current that creeps up is an early sign of a load or bearing problem. Read run status beside it, so a heavy load is seen for what it is.
Generator controller
Oil pressure, coolant temperature, run status and battery voltage over Modbus, with an alarm when one leaves its range. J1939 engine data on request.
Energy meter
Power and demand from a Modbus energy meter, and an alarm when a circuit that should be running stops drawing power.
If it speaks Modbus, we can read it
Send us the machine's manual or register map. We tell you what we can read before you buy anything.
1. Send the manual
Tell us the make and model, and send the manual or the list of registers. We reply with what we can read.
2. We map the registers with you
Which values to read, their units and scaling, and how often.
3. The gateway goes in, read-only
Powoflow Sense Mesa connects to the machine's RS-485 Modbus line, agreed with whoever looks after the controls.
4. First readings, checked together
We check the first readings against the machine's own display. Then you set the limits and the alarms.
What the gateway reads
A plain status for each, so you know what has run and what we set up on request.
Modbus RTU over RS-485
In production. The gateway has two RS-485 ports.
Modbus TCP over your network
On request.
CAN / J1939 engine data
On request.
Vehicle diagnostics (OBD-II)
On request.
Not listed?
Send us the manual, and we tell you whether we can read it.
Safe for your plant
Read-only by design
The gateway can only read Modbus registers. It cannot write to your PLC or change a setpoint.
No change to your control program
Nothing is installed on the PLC, and its program stays as it is.
It connects out
The gateway connects out to Powoflow over an encrypted link, with its own certificate.
Control is separate
Control of a pump or a valve is a separate setup, on request, through the gateway's own outputs, never by writing to your PLC.
What it does not do yet
- Each machine is set up with you from its register map. There is no library of ready-made machine profiles yet.
- Modbus over your network, CAN / J1939 and vehicle diagnostics are set up on request and have not yet run at a customer site.
- A local store that keeps readings through an outage and backfills them afterwards is being built.
- Powoflow is not a SCADA system and does not replace one. It reads, records, raises alarms and organises the work.
Start with one machine
Pick the machine that worries you most. Tell us the make and model and send the manual; a person replies within one working day with what we can read.